Education/Shaping
PT progressive-taper technique
Open the coronal path, prepare the middle third, and select the finishing size from the canal.
Chairside sequence
Step by step
- 01
Prepare access and glide path
Establish working length, irrigation access, and a reproducible pathway.
- 02
Refine coronally
Use SX conservatively where coronal enlargement is required. Preserve dentine and remain oriented to the root.
- 03
Shape the middle third
Progress through S1 and S2 with short controlled engagements, cleaning and irrigating between instruments.
- 04
Finish selectively
Use the appropriate finishing file and assess the apical preparation before obturation.
The finishing file is selected by anatomy and apical assessment, not by completing the entire pack.
Avoid prolonged engagement
Withdraw when resistance increases. Clean the flutes and irrigate before continuing. Verify that the glide path and working length remain reproducible.
Match the motor to the instrument
The NZ source lists 300 rpm and 3.0 N·cm for its PT sequence. Check the current USA product instructions before clinical use.
Reference table
| Instrument | Tip size | Taper |
|---|---|---|
| SX | 19 | Progressive |
| S1 | 17 | Progressive |
| S2 | 20 | Progressive |
| F1 | 20 | .07 |
| F2 | 25 | .08 |
| F3 | 30 | .09 |
Sources & further reading
Read the source material
Adapted for the EndoTech USA education library. NZ reference documents retain their original edition and branding.
Continue reading
All guides →Shaping
Motor settings and file selection
Check speed, torque, and the correct file sequence before the first instrument enters the canal.
Shaping
ET constant-taper protocol
MicroPath glide preparation, ET opening and 17/.04 to 25/.04 shaping, with the illustrated file sequence and EndoTech motor settings.
Disinfection
Irrigation that reaches beyond the file
Fresh chemistry, controlled delivery, and enough contact time to work in the anatomy instruments cannot reach.